Electrolyte for general Li-ion battery JP-01
Application
- This product is designed for Aluminum shell cell using LiCoO2 as cathode material and artificial graphite as anode material.
- It has good comprehensive performance and the cell using it will have good cycle life and could against swelling.
Composition
Ester solvents | LiPF6 | additive, etc. |
Specification
Item | Spec. | Testing Method |
---|---|---|
Colority | ≤ 20 Hazen | Pt/Co scale |
Water | ≤ 20 ppm | Karl-Fischer titration |
Free acid (as HF) | ≤ 50 ppm | Neutralization |
Metal | ≤ 10 ppm | Atomic Absorption |
Density(25℃) | 1.20±0.03 g/cm3 | Pycnometer |
Conductivity(25℃) | 9.0±0.5 mS/cm | Conductivity meter |
Custom Test Result
Charge-discharge efficiency at first cycle (%) | Capacity retention at ambient temperature (%) | Discharges platform maintenance rate (%) | Expansion rate | |||
---|---|---|---|---|---|---|
100 cycle | 200 cycle | 100 cycle | 200 cycle | 100 cycle | 200 cycle | |
>92 | >96 | >94 | >99 | >97 | <1 | <3 |
Electrolyte for general Li-ion battery JP-04
Application
- This product is designed for Aluminum or Steel shell cell using LiCoO2 as cathode material and artificial or natural graphite as anode material.
- It has good comprehensive performance and the cell using it will have good cycle life and could against swelling.
Composition
Ester solvents | LiPF6 | additive, etc. |
Specification
Item | Spec. | Testing Method |
---|---|---|
Colority | ≤ 20 Hazen | Pt/Co scale |
Water | ≤ 20 ppm | Karl-Fischer titration |
Free acid (as HF) | ≤ 50 ppm | Neutralization |
Metal | ≤ 10 ppm | Atomic Absorption |
Density(25℃) | 1.21±0.03 g/cm3 | Pycnometer |
Conductivity(25℃) | 10.0±0.5 mS/cm | Conductivity meter |
Custom Test Result
Charge-discharge efficiency at first cycle (%) | Capacity retention at ambient temperature (%) | Discharges platform maintenance rate (%) | Expansion rate | |||
---|---|---|---|---|---|---|
100 cycle | 200 cycle | 100 cycle | 200 cycle | 100 cycle | 200 cycle | |
>92 | >95 | >93 | >99.5 | >96.5 | <1 | <3 |
Electrolyte for general Li-ion battery JP-05
Application
- This product is designed for Aluminum or Steel shell cell using LiMnO4 as cathode material and artificial graphite as anode material.
- It has good comprehensive performance and the cell using it will have good cycle life and could against swelling.
Composition
Ester solvents | LiPF6 | additive, etc. |
Specification
Item | Spec. | Testing Method |
---|---|---|
Colority | ≤ 20 Hazen | Pt/Co scale |
Water | ≤ 20 ppm | Karl-Fischer titration |
Free acid (as HF) | ≤ 50 ppm | Neutralization |
Metal | ≤ 10 ppm | Atomic Absorption |
Density(25℃) | 1.23±0.03 g/cm3 | Pycnometer |
Conductivity(25℃) | 10.5±0.5 mS/cm | Conductivity meter |
Custom Test Result
Charge-discharge efficiency at first cycle (%) | Capacity retention at ambient temperature (%) | Discharges platform maintenance rate (%) | Expansion rate | |||
---|---|---|---|---|---|---|
100 cycle | 200 cycle | 100 cycle | 200 cycle | 100 cycle | 200 cycle | |
>92 | >95 | >93 | >99 | >97.5 | <1 | <3 |
Electrolyte for general Li-ion battery JP-07
Application
- This product is designed for Aluminum shell cell using LiCoO2 as cathode material and artificial graphite as anode material.
- It has good comprehensive performance and the cell using it will have good cycle life and could against swelling.
Composition
Ester solvents | LiPF6 | additive, etc. |
Specification
Item | Spec. | Testing Method |
---|---|---|
Colority | ≤ 20 Hazen | Pt/Co scale |
Water | ≤ 20 ppm | Karl-Fischer titration |
Free acid (as HF) | ≤ 50 ppm | Neutralization |
Metal | ≤ 10 ppm | Atomic Absorption |
Density(25℃) | 1.20±0.03 g/cm3 | Pycnometer |
Conductivity(25℃) | 9.5±0.5 mS/cm | Conductivity meter |
Custom Test Result
Charge-discharge efficiency at first cycle (%) | Capacity retention at ambient temperature (%) | Discharges platform maintenance rate (%) | Expansion rate (%) | |||
---|---|---|---|---|---|---|
100 cycle | 200 cycle | 100 cycle | 200 cycle | 100 cycle | 200 cycle | |
>90 | >96 | >95 | >99 | >97.5 | <1 | <5 |